CAPL Script

TestWaitForValueFloat

Syntax

long TestWaitForValueFloat(COValue value, float awaitedValue, dword timeoutMs)

Function

Waits for a communication object value to reach a certain value. This function can only be used for communication object values with a floating point data type. It cannot be used for system variables or bus system signals.

Parameters

awaitedValue Value which is awaited.

timeoutMS

Timeout in milliseconds.

Return Values

-2: Resume due to constraint violation

-1: General error, for example, functionality is not available

0: Resume due to timeout

1: resume due to event occurred (value has been reached)

long ret;ret = testWaitForValueFloat(MirrorStatus[CANoe].Temperature, 20.0, 200);